Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6PMA

TRK-A IN COMPLEX WITH LIGAND

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2015-11-20
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.0
Spacegroup nameP 31 1 2
Unit cell lengths52.094, 52.094, 227.160
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution45.160 - 2.530
R-factor0.2091
Rwork0.204
R-free0.26630
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.012
RMSD bond angle1.834
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0238)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]75.7202.760
High resolution limit [Å]2.5102.510
Number of reflections121462755
<I/σ(I)>18.2
Completeness [%]97.290.2
Redundancy4.24.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2770.10M KH2PO4/ 0.10M NaH2PO4/ 0.1M MES/NaOH pH = 6.00 and 1.9M NaCl (cryo: 25% glycerol in reservoir), or 18% (w/v) PEG 3350, 0.2M CaCl2, 0.10M, MES pH = 6.50 (cryo: direct).

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon