6PGN
PagF single mutant with GPP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-G |
Synchrotron site | APS |
Beamline | 21-ID-G |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-10-26 |
Detector | RAYONIX MX300HE |
Wavelength(s) | 0.978560 |
Spacegroup name | P 65 |
Unit cell lengths | 116.662, 116.662, 43.681 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 25.000 - 1.850 |
R-factor | 0.19034 |
Rwork | 0.189 |
R-free | 0.21556 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5tty |
RMSD bond length | 0.008 |
RMSD bond angle | 1.272 |
Data reduction software | HKL-2000 |
Data scaling software | autoPROC |
Phasing software | SHARP |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 73.600 | 1.856 |
High resolution limit [Å] | 1.850 | 1.850 |
Number of reflections | 29288 | |
<I/σ(I)> | 24.6 | |
Completeness [%] | 100.0 | |
Redundancy | 15.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 282 | lithium sulfate, PEG3350 |