6PGN

PagF single mutant with GPP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-G
Synchrotron siteAPS
Beamline21-ID-G
Temperature [K]100
Detector technologyCCD
Collection date2016-10-26
DetectorRAYONIX MX300HE
Wavelength(s)0.978560
Spacegroup nameP 65
Unit cell lengths116.662, 116.662, 43.681
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution25.000 - 1.850
R-factor0.19034
Rwork0.189
R-free0.21556
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5tty
RMSD bond length0.008
RMSD bond angle1.272
Data reduction softwareHKL-2000
Data scaling softwareautoPROC
Phasing softwareSHARP
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]73.6001.856
High resolution limit [Å]1.8501.850
Number of reflections29288
<I/σ(I)>24.6
Completeness [%]100.0
Redundancy15.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP282lithium sulfate, PEG3350

231029

PDB entries from 2025-02-05