Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6OWY

Spy H96L:Im7 K20pI-Phe complex; multiple anomalous datasets contained herein for element identification

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I23
Synchrotron siteDiamond
BeamlineI23
Temperature [K]75
Detector technologyPIXEL
Collection date2017-10-24
DetectorDECTRIS PILATUS 2M
Wavelength(s)2.3843, 2.7552
Spacegroup nameP 41 2 2
Unit cell lengths42.840, 42.840, 257.630
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.840 - 2.070
R-factor0.23
Rwork0.227
R-free0.27280
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5wnw
RMSD bond length0.013
RMSD bond angle1.227
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]42.8402.120
High resolution limit [Å]2.0702.070
Number of reflections157621115
<I/σ(I)>18.9
Completeness [%]99.7
Redundancy7.7
CC(1/2)0.9990.691
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29322-34% PEG 3000, 70-270 mM zinc acetate, and 0.1 M imidazole, pH 8.0

219869

PDB entries from 2024-05-15