6OBR
PP1 Y134A in complex with Microcystin LR
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-2 |
Synchrotron site | SSRL |
Beamline | BL12-2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-02-05 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.98 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 64.932, 76.550, 131.213 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.275 - 1.500 |
R-factor | 0.1889 |
Rwork | 0.188 |
R-free | 0.21010 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4mov |
RMSD bond length | 0.015 |
RMSD bond angle | 0.917 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.11.1_2575: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.280 | 1.520 |
High resolution limit [Å] | 1.500 | 1.500 |
Rmerge | 0.083 | 1.127 |
Number of reflections | 105369 | 5069 |
<I/σ(I)> | 9.6 | |
Completeness [%] | 99.8 | |
Redundancy | 7.7 | |
CC(1/2) | 0.998 | 0.691 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 289 | 20% PEG6000, 1 M lithium chloride, 0.1 M MES |