6O17
Recombinant Human Insulin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-05-17 |
Detector | MAR CCD 130 mm |
Wavelength(s) | 1.5418 |
Spacegroup name | I 21 3 |
Unit cell lengths | 77.633, 77.633, 77.633 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 31.710 - 1.580 |
R-factor | 0.18346 |
Rwork | 0.182 |
R-free | 0.20112 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5viz |
RMSD bond length | 0.015 |
RMSD bond angle | 1.983 |
Data reduction software | HKL-2000 (2.3.8) |
Data scaling software | HKL-2000 (2.3.8) |
Phasing software | CrystalClear (2.3.8) |
Refinement software | REFMAC (5.8.0107) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.610 |
High resolution limit [Å] | 1.580 | 1.580 |
Rmerge | 0.043 | |
Rpim | 0.421 | 0.421 |
Number of reflections | 10867 | 541 |
<I/σ(I)> | 67.3 | |
Completeness [%] | 100.0 | |
Redundancy | 7.7 | |
CC(1/2) | 0.646 | 0.646 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | BATCH MODE | 298 | PEG 6000 30% |