Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6NTB

PII-like SbtB from Cyanobium sp PCC 7001 bound to ATP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX2
Synchrotron siteAustralian Synchrotron
BeamlineMX2
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-12
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9537
Spacegroup nameP 62
Unit cell lengths132.946, 132.946, 33.837
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution43.520 - 1.900
Rwork0.195
R-free0.22700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6mm2
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]43.5201.940
High resolution limit [Å]1.9001.900
Rmerge0.107
Rmeas0.112
Rpim0.0350.925
Number of reflections274682714
<I/σ(I)>15.81.2
Completeness [%]100.0100
Redundancy2018.1
CC(1/2)0.9990.560
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP82930.2 M Lithium Chloride, 20 % PEG 6000, 100 mM sodium acetate-acetic acid, pH 5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon