6NFV
Structure of the KcsA-G77C mutant or the 2,4-ion bound configuration of a K+ channel selectivity filter.
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRL BEAMLINE BL14-1 |
| Synchrotron site | SSRL |
| Beamline | BL14-1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-11-25 |
| Detector | MARMOSAIC 325 mm CCD |
| Wavelength(s) | 0.987 |
| Spacegroup name | I 4 |
| Unit cell lengths | 156.158, 156.158, 76.116 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.918 - 2.130 |
| R-factor | 0.2071 |
| Rwork | 0.206 |
| R-free | 0.24280 |
| Data reduction software | HKL-2000 (v1.0) |
| Data scaling software | HKL-2000 (v1.0) |
| Refinement software | PHENIX (1.13_2998) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 34.918 | 2.200 |
| High resolution limit [Å] | 2.130 | 2.130 |
| Number of reflections | 51020 | |
| <I/σ(I)> | 33.74 | |
| Completeness [%] | 99.3 | |
| Redundancy | 3.3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | PEG400 , magnesium acetate, sodium acetate |