6NC1
FtsY-NG high-resolution
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-05-06 |
Detector | ADSC QUANTUM 210r |
Wavelength(s) | 0.9537 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 34.367, 75.980, 108.265 |
Unit cell angles | 90.00, 90.30, 90.00 |
Refinement procedure
Resolution | 37.990 - 1.598 |
R-factor | 0.1714 |
Rwork | 0.170 |
R-free | 0.20080 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6cqp |
RMSD bond length | 0.006 |
RMSD bond angle | 0.867 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.13_2998: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 37.990 | 1.600 |
High resolution limit [Å] | 1.598 | 1.598 |
Number of reflections | 72072 | |
<I/σ(I)> | 18.33 | |
Completeness [%] | 97.8 | |
Redundancy | 2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 297.15 | 0.1 M Bis-Tris pH 7, 30% PEG 2000 MME, 150 mM KBr |