6MT7
Phlebotomus duboscqi salivary D7 protein, selenomethionine derivative
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-10-25 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 0.97499 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 143.908, 101.515, 33.539 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 43.371 - 1.780 |
R-factor | 0.1702 |
Rwork | 0.168 |
R-free | 0.20620 |
Structure solution method | SAD |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 10.000 | 1.810 |
High resolution limit [Å] | 1.780 | 4.830 | 1.780 |
Rmerge | 0.065 | 0.043 | 0.194 |
Rmeas | 0.074 | 0.049 | 0.229 |
Rpim | 0.033 | 0.022 | 0.118 |
Number of reflections | 90692 | 4540 | 4486 |
<I/σ(I)> | 12.4 | ||
Completeness [%] | 99.7 | 99.9 | 98.7 |
Redundancy | 4.5 | 4.8 | 3.4 |
CC(1/2) | 0.998 | 0.953 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 20% PEG 6000m 0.1M MES pH 6 |