6MRI
E. coli cysteine desulfurase SufS E250A with a cysteine persulfide intermediate
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-03-30 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.000 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 125.730, 125.730, 138.550 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 60.675 - 2.620 |
R-factor | 0.1867 |
Rwork | 0.184 |
R-free | 0.22000 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1jf9 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.14_3211) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 60.675 | 60.675 | 2.690 |
High resolution limit [Å] | 2.620 | 11.720 | 2.620 |
Rmerge | 0.157 | 0.049 | 0.697 |
Rmeas | 0.169 | 0.052 | 0.757 |
Number of reflections | 31408 | 391 | 2327 |
<I/σ(I)> | 6.79 | 11.76 | 2.09 |
Completeness [%] | 92.4 | 85.7 | 94.9 |
Redundancy | 7.044 | 6.317 | 7.398 |
CC(1/2) | 0.989 | 0.998 | 0.592 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 293 | 4-4.5 M sodium chloride, 100 mM MES |