Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6LJG

Crassostrea gigas ferritin mutant-D119G

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U1
Synchrotron siteSSRF
BeamlineBL17U1
Temperature [K]93
Detector technologyPIXEL
Collection date2019-11-09
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9785
Spacegroup nameI 4 3 2
Unit cell lengths151.134, 151.134, 151.134
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution26.717 - 1.799
R-factor0.1936
Rwork0.192
R-free0.21470
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1fha
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwareHKL-3000
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]26.7201.864
High resolution limit [Å]1.7991.799
Number of reflections276592700
<I/σ(I)>311
Completeness [%]99.9
Redundancy38.8
CC(1/2)1.0001.000
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION293PEG 8000, CAPS/Sodium hydroxide, Sodium chloride

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon