6KJW

Galectin-13 variant C136S

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL18U1
Synchrotron siteSSRF
BeamlineBL18U1
Temperature [K]100
Detector technologyPIXEL
Collection date2019-04-21
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97
Spacegroup nameP 43 21 2
Unit cell lengths53.438, 53.438, 113.839
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.501 - 1.360
R-factor0.1939
Rwork0.193
R-free0.20170
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.009
RMSD bond angle1.047
Refinement softwarePHENIX (1.12_2829)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.5011.380
High resolution limit [Å]1.3601.360
Number of reflections362781753
<I/σ(I)>28.8
Completeness [%]99.9
Redundancy6.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP298Bis-Tris

220113