6KGI
RLGS-yUbr1 Ubr box
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PHOTON FACTORY BEAMLINE BL-17A |
Synchrotron site | Photon Factory |
Beamline | BL-17A |
Temperature [K] | 193 |
Detector technology | PIXEL |
Collection date | 2018-05-04 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.90000 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 60.630, 60.630, 69.811 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.250 - 1.040 |
R-factor | 0.1898 |
Rwork | 0.189 |
R-free | 0.20180 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3nit |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.060 |
High resolution limit [Å] | 1.040 | 1.040 |
Number of reflections | 62982 | 6200 |
<I/σ(I)> | 43.9 | |
Completeness [%] | 100.0 | |
Redundancy | 12.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.1M BIS-Tris pH 6.5, 2.7-3.0M NaCl |