6JW1
Universal RVD R* accommodates 5mC via water-mediated interactions
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-10-01 |
Detector | MAR CCD 130 mm |
Wavelength(s) | 0.9793 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 85.787, 87.378, 88.456 |
Unit cell angles | 90.00, 104.23, 90.00 |
Refinement procedure
Resolution | 85.740 - 2.490 |
R-factor | 0.2318 |
Rwork | 0.229 |
R-free | 0.27840 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4gjp |
RMSD bond length | 0.010 |
RMSD bond angle | 1.546 |
Data reduction software | HKL-3000 |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0049) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 85.740 | 2.530 |
High resolution limit [Å] | 2.490 | 2.490 |
Rmeas | 0.139 | 0.139 |
Number of reflections | 41879 | |
<I/σ(I)> | 2 | |
Completeness [%] | 97.5 | |
Redundancy | 3.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 8-10% PEG3350 (w/v), 10% ethanol and 0.1M MES pH 6.7 |