Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6J9K

Apo-AcrIIC2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL18U1
Synchrotron siteSSRF
BeamlineBL18U1
Temperature [K]193
Detector technologyPIXEL
Collection date2017-08-22
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9785
Spacegroup nameP 63 2 2
Unit cell lengths72.022, 72.022, 105.230
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution40.217 - 2.234
R-factor0.2095
Rwork0.206
R-free0.24290
Structure solution methodSAD
RMSD bond length0.010
RMSD bond angle1.213
Data scaling softwareHKL-3000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.8.1_1168)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.300
High resolution limit [Å]2.2302.230
Rmerge0.0944.078
Number of reflections8250599
<I/σ(I)>28.9
Completeness [%]98.381.3
Redundancy35.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.1M Tris, ethanol

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon