6J9K
Apo-AcrIIC2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 193 |
Detector technology | PIXEL |
Collection date | 2017-08-22 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9785 |
Spacegroup name | P 63 2 2 |
Unit cell lengths | 72.022, 72.022, 105.230 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 40.217 - 2.234 |
R-factor | 0.2095 |
Rwork | 0.206 |
R-free | 0.24290 |
Structure solution method | SAD |
RMSD bond length | 0.010 |
RMSD bond angle | 1.213 |
Data scaling software | HKL-3000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.8.1_1168) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.300 |
High resolution limit [Å] | 2.230 | 2.230 |
Rmerge | 0.094 | 4.078 |
Number of reflections | 8250 | 599 |
<I/σ(I)> | 28.9 | |
Completeness [%] | 98.3 | 81.3 |
Redundancy | 35.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.1M Tris, ethanol |