6IZB
Flexible loop truncated human TCTP
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | FREE ELECTRON LASER |
| Source details | SwissFEL ARAMIS BEAMLINE ESA |
| Synchrotron site | SwissFEL ARAMIS |
| Beamline | ESA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2011-05-21 |
| Detector | DECTRIS PILATUS3 R CdTe 300K |
| Wavelength(s) | 1.000 |
| Spacegroup name | P 61 2 2 |
| Unit cell lengths | 69.295, 69.295, 146.062 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 46.366 - 1.899 |
| R-factor | 0.2209 |
| Rwork | 0.220 |
| R-free | 0.24590 |
| RMSD bond length | 0.019 |
| RMSD bond angle | 1.187 |
| Data reduction software | iMOSFLM |
| Data scaling software | pointless |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.13_2998: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 46.370 | 1.970 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Number of reflections | 17029 | |
| <I/σ(I)> | 45.7 | |
| Completeness [%] | 99.5 | |
| Redundancy | 36.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 296 | 0.1 M MES pH 6.5, 25 % (w/v) PEG 300 |