6IPN
Binary Complex of Human DNA Polymerase Mu with MgdGTP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE TPS 05A |
Synchrotron site | NSRRC |
Beamline | TPS 05A |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-05-27 |
Detector | RAYONIX MX300-HS |
Wavelength(s) | 1 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 124.776, 124.776, 50.549 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.000 - 1.600 |
R-factor | 0.2092 |
Rwork | 0.208 |
R-free | 0.23610 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.443 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.660 |
High resolution limit [Å] | 1.600 | 1.600 |
Rmeas | 0.061 | 0.729 |
Rpim | 0.016 | 0.230 |
Number of reflections | 53029 | 5125 |
<I/σ(I)> | 44.91 | 2.88 |
Completeness [%] | 99.7 | 98.1 |
Redundancy | 13.8 | 9.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 298 | 0.1 M HEPES pH 7.5, 1.5 M Li2SO4 |