6ICS
Loop deletion mutant (deleting four residues)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PHOTON FACTORY BEAMLINE BL-1A |
| Synchrotron site | Photon Factory |
| Beamline | BL-1A |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2016-12-02 |
| Detector | DECTRIS EIGER R 4M |
| Wavelength(s) | 1.0000 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 33.030, 54.065, 65.952 |
| Unit cell angles | 90.00, 100.35, 90.00 |
Refinement procedure
| Resolution | 19.686 - 1.400 |
| R-factor | 0.1805 |
| Rwork | 0.179 |
| R-free | 0.20100 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2g8c |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.838 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | MOLREP |
| Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 1.420 |
| High resolution limit [Å] | 1.400 | 1.400 |
| Rmerge | 0.119 | 0.365 |
| Number of reflections | 45139 | 2252 |
| <I/σ(I)> | 21.4 | 2.24 |
| Completeness [%] | 99.5 | 99.7 |
| Redundancy | 3.2 | 3.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 292 | 40% w/v PEG 400, 0.1M Imidazole |