6ICR

LdCoroCC mutant- C482A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Temperature [K]100
Detector technologyCCD
Collection date2011-09-08
DetectorMAR CCD 130 mm
Wavelength(s)0.97625
Spacegroup nameC 1 2 1
Unit cell lengths117.480, 49.720, 45.730
Unit cell angles90.00, 110.59, 90.00
Refinement procedure
Resolution33.644 - 2.040
R-factor0.2654
Rwork0.263
R-free0.30530
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5cx2
RMSD bond length0.004
RMSD bond angle0.665
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]33.6442.382
High resolution limit [Å]2.0402.300
Rmerge0.0440.066
Rmeas0.0470.071
Number of reflections158391103
<I/σ(I)>16.1612.44
Completeness [%]99.699.82
Redundancy7.6
CC(1/2)0.9990.999
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.6298Lithium sulfate 0.8M, ammonium sulfate 0.85M, sodium citrate buffer 0.1M