6H4A
Human MALT1(329-728) in complex with MLT-748
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-04-29 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 1 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 94.930, 68.930, 56.750 |
Unit cell angles | 90.00, 92.65, 90.00 |
Refinement procedure
Resolution | 47.410 - 2.650 |
R-factor | 0.192 |
Rwork | 0.190 |
R-free | 0.24000 |
Structure solution method | FOURIER SYNTHESIS |
Starting model (for MR) | 3v55 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.210 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Refinement software | BUSTER (2.11.7) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.410 | 2.660 |
High resolution limit [Å] | 2.650 | 2.650 |
Rmerge | 0.073 | 0.768 |
Number of reflections | 10676 | |
<I/σ(I)> | 9 | 1.6 |
Completeness [%] | 99.5 | 100 |
Redundancy | 3.3 | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 293 | PEG 2000 0.1M Mes pH 6.5 |