Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6GXD

The hit-and-return system enables efficient time-resolved serial synchrotron crystallography: FAcD752MS after reaction initiation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, DESY BEAMLINE P11
Synchrotron sitePETRA III, DESY
BeamlineP11
Temperature [K]293
Detector technologyPIXEL
Collection date2017-05-01
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.00890
Spacegroup nameP 1 21 1
Unit cell lengths41.370, 78.540, 83.510
Unit cell angles90.00, 102.76, 90.00
Refinement procedure
Resolution40.724 - 1.800
R-factor0.1673
Rwork0.165
R-free0.20900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3r3u
RMSD bond length0.016
RMSD bond angle1.550
Data reduction softwareXDS (nXDS)
Data scaling softwareXSCALE (nXSCALE)
Phasing softwarePHASER
Refinement softwarePHENIX ((1.12_2829: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]81.5001.830
High resolution limit [Å]1.8001.800
Number of reflections48357
<I/σ(I)>5.3
Completeness [%]99.9
Redundancy39.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE293PEG 3350, 18-20 (w/v) CaCl2, 100 mM Tris HCl, 100 mM pH 8.5

246031

PDB entries from 2025-12-10

PDB statisticsPDBj update infoContact PDBjnumon