6GUK
CDK2 in complex with CGP74514A
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04 |
Synchrotron site | Diamond |
Beamline | I04 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-03-04 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.987 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 53.291, 71.938, 72.391 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 51.080 - 1.300 |
R-factor | 0.20569 |
Rwork | 0.204 |
R-free | 0.23204 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5mhq |
RMSD bond length | 0.023 |
RMSD bond angle | 2.178 |
Data reduction software | xia2 |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 51.080 | 1.320 |
High resolution limit [Å] | 1.300 | 1.300 |
Rmerge | 0.040 | |
Number of reflections | 69081 | |
<I/σ(I)> | 15.5 | 1.3 |
Completeness [%] | 100.0 | 100 |
Redundancy | 6.9 | 6.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 10MG/ML CDK2 10% V/V PEG3350, 50 MM HEPES/NAOH, 50 MM NA/K PHOSPHATE, PH 7.5 |