Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6G5E

MamM CTD H264A-E289A-C267S

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2018-02-01
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.975
Spacegroup nameC 2 2 21
Unit cell lengths37.027, 94.793, 53.499
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.480 - 1.600
R-factor0.2087
Rwork0.206
R-free0.25680
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3w5x
RMSD bond length0.006
RMSD bond angle0.805
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.4001.620
High resolution limit [Å]1.6001.600
Rmerge0.029
Rmeas0.032
Rpim0.013
Number of reflections12814553
<I/σ(I)>26.92.2
Completeness [%]99.286.5
Redundancy6.45.8
CC(1/2)0.9990.931
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.2M Li2SO4, 0.1M BIS-TRIS pH=5.5, 25% PEG 3350