6FRA
F11 T-Cell Receptor Recognising PKYVKQNTLKLAT Peptide Presented by HLA-DR*0101
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2012-10-13 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.9200 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 85.710, 114.630, 50.660 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.640 - 1.730 |
R-factor | 0.20545 |
Rwork | 0.203 |
R-free | 0.24339 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6eh6 |
RMSD bond length | 0.019 |
RMSD bond angle | 2.038 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.640 | 1.780 |
High resolution limit [Å] | 1.730 | 1.730 |
Rmerge | 0.060 | 0.783 |
Rmeas | 0.065 | 0.847 |
Number of reflections | 52808 | 3853 |
<I/σ(I)> | 19.2 | |
Completeness [%] | 99.9 | 100 |
Redundancy | 6.6 | 6.9 |
CC(1/2) | 0.999 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 291 | 30% PEG 8K, 0.1M MES, 0.2M Na Acetate |