6FQE
Phosphotriesterase PTE_A53_4
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RUH3R |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2014-06-06 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5141 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 54.550, 81.300, 70.610 |
Unit cell angles | 90.00, 94.96, 90.00 |
Refinement procedure
Resolution | 30.143 - 1.750 |
R-factor | 0.1611 |
Rwork | 0.160 |
R-free | 0.18650 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1hzy |
RMSD bond length | 0.006 |
RMSD bond angle | 0.934 |
Data reduction software | HKL-3000 |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX ((1.11.1-2575_1692: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.143 | 1.813 |
High resolution limit [Å] | 1.750 | 1.750 |
Rmerge | 0.026 | 0.163 |
Number of reflections | 58412 | 5591 |
<I/σ(I)> | 18.96 | 4.57 |
Completeness [%] | 94.3 | 90.59 |
Redundancy | 7.6 | 7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 12% PEG 8000 0.05M Tris pH=7.5 |