6F0V
GLIC mutant E82Q
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 190 |
Detector technology | PIXEL |
Collection date | 2015-02-16 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.9762 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 179.340, 132.500, 158.310 |
Unit cell angles | 90.00, 101.21, 90.00 |
Refinement procedure
Resolution | 48.970 - 2.850 |
R-factor | 0.2024 |
Rwork | 0.201 |
R-free | 0.22090 |
RMSD bond length | 0.010 |
RMSD bond angle | 1.090 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.2) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.970 | 3.010 |
High resolution limit [Å] | 2.850 | 2.850 |
Number of reflections | 84182 | |
<I/σ(I)> | 6.6 | |
Completeness [%] | 99.5 | |
Redundancy | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 293 | 12% PEG4K, 15% glycerol, 100 mM Acetate de Sodium pH4, 200 mM Sodium isothiocyanate, 3% DMSO |