Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6F0J

GLIC mutant E26A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]190
Detector technologyPIXEL
Collection date2015-05-06
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.98
Spacegroup nameC 1 2 1
Unit cell lengths181.010, 133.110, 159.850
Unit cell angles90.00, 102.14, 90.00
Refinement procedure
Resolution25.000 - 3.150
R-factor0.2084
Rwork0.208
R-free0.22210
RMSD bond length0.009
RMSD bond angle1.020
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.2)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.6903.150
High resolution limit [Å]3.0003.000
Number of reflections64088
<I/σ(I)>10.2
Completeness [%]99.8
Redundancy3.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION29212% PEG4K, 15% glycerol, 100 mM Acetate de Sodium pH4, 400 mM Sodium isothiocyanate, 3% DMSO

219869

PDB entries from 2024-05-15