6EWL
Danio rerio CEP120 first C2 domain (C2A)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I02 |
Synchrotron site | Diamond |
Beamline | I02 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-10-07 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97949 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 31.459, 53.440, 74.659 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 30.603 - 1.400 |
R-factor | 0.1647 |
Rwork | 0.163 |
R-free | 0.20210 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | C2 domain homology model |
RMSD bond length | 0.012 |
RMSD bond angle | 1.222 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX ((1.11.1_2575: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 31.460 | 1.480 |
High resolution limit [Å] | 1.400 | 1.400 |
Rmerge | 0.049 | |
Rmeas | 0.054 | |
Rpim | 0.022 | 0.435 |
Number of reflections | 25380 | |
<I/σ(I)> | 14.1 | 1.7 |
Completeness [%] | 99.3 | 98.1 |
Redundancy | 5.9 | 6.1 |
CC(1/2) | 0.999 | 0.533 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 292 | 100 mM HEPES, pH 7.5 200 mM MgCl2 30 % (v/v) PEG-400 |