6EQ4
MTH1 in complex with fragment 8
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-05-12 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 60.673, 65.939, 35.887 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.887 - 1.400 |
R-factor | 0.1678 |
Rwork | 0.166 |
R-free | 0.18740 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.032 |
Data reduction software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.480 |
High resolution limit [Å] | 1.400 | 1.400 |
Rmeas | 0.059 | 0.095 |
Number of reflections | 54076 | 8674 |
<I/σ(I)> | 18.96 | 10.99 |
Completeness [%] | 98.4 | 97.6 |
Redundancy | 3.4 | 3.11 |
CC(1/2) | 0.996 | 0.987 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4.5 | 293 | 23 % PEG3350, 0.2 M LI2SO4, 0.1 M SODIUM ACETATE PH 4.5 |