Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ELETTRA BEAMLINE 5.2R |
| Synchrotron site | ELETTRA |
| Beamline | 5.2R |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2001-04-04 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 1.0 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 74.563, 93.324, 37.456 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 31.505 - 2.022 |
| R-factor | 0.2134 |
| Rwork | 0.211 |
| R-free | 0.25500 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1nxt |
| RMSD bond length | 0.014 |
| RMSD bond angle | 1.643 |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.13_2998: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 31.510 | 2.250 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Number of reflections | 6892 | 682 |
| <I/σ(I)> | 2 | |
| Completeness [%] | 93.8 | 95.09 |
| Redundancy | 2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 7 | 298 | 30% (vol/vol) polyethylene glycol 300 (PEG-300), 0.1 M Tris-HCl buffer (pH 7.0) |