6E3J
Human Bfl-1 in complex with the Bfl-1-specific designed peptide srt.F10
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-10-14 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.97910 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 43.266, 42.907, 47.029 |
Unit cell angles | 90.00, 114.73, 90.00 |
Refinement procedure
Resolution | 42.716 - 1.482 |
R-factor | 0.1459 |
Rwork | 0.143 |
R-free | 0.17780 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.13_2998) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 1.510 |
High resolution limit [Å] | 1.480 | 4.020 | 1.480 |
Rmerge | 0.059 | 0.039 | 0.310 |
Rmeas | 0.065 | 0.043 | 0.366 |
Rpim | 0.026 | 0.017 | 0.189 |
Number of reflections | 25487 | 1358 | 1008 |
<I/σ(I)> | 7.2 | ||
Completeness [%] | 97.5 | 98.9 | 80.3 |
Redundancy | 5.4 | 6.2 | 2.9 |
CC(1/2) | 0.998 | 0.864 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | 1.8 M ammonium sulfate, 0.1 M MES pH 7.0 |