6E3J
Human Bfl-1 in complex with the Bfl-1-specific designed peptide srt.F10
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2017-10-14 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.97910 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 43.266, 42.907, 47.029 |
| Unit cell angles | 90.00, 114.73, 90.00 |
Refinement procedure
| Resolution | 42.716 - 1.482 |
| R-factor | 0.1459 |
| Rwork | 0.143 |
| R-free | 0.17780 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.13_2998) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 1.510 |
| High resolution limit [Å] | 1.480 | 4.020 | 1.480 |
| Rmerge | 0.059 | 0.039 | 0.310 |
| Rmeas | 0.065 | 0.043 | 0.366 |
| Rpim | 0.026 | 0.017 | 0.189 |
| Number of reflections | 25487 | 1358 | 1008 |
| <I/σ(I)> | 7.2 | ||
| Completeness [%] | 97.5 | 98.9 | 80.3 |
| Redundancy | 5.4 | 6.2 | 2.9 |
| CC(1/2) | 0.998 | 0.864 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 298 | 1.8 M ammonium sulfate, 0.1 M MES pH 7.0 |