Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6DGV

iGABASnFR Fluorescent GABA Sensor precursor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.2
Synchrotron siteALS
Beamline8.2.2
Temperature [K]100
Detector technologyCCD
Collection date2015-06-05
DetectorADSC QUANTUM 315r
Wavelength(s)1
Spacegroup nameP 64
Unit cell lengths160.970, 160.970, 50.071
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution139.400 - 2.800
R-factor0.17777
Rwork0.175
R-free0.22830
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4EQ7 and the cpGFP component of 3OSR
RMSD bond length0.013
RMSD bond angle1.818
Data reduction softwareMOSFLM
Data scaling softwareSCALA (3.3.22)
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0123)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]139.4042.950
High resolution limit [Å]2.8002.800
Rmerge0.3620.025
Rmeas0.3702.560
Rpim0.0800.549
Number of reflections186212692
<I/σ(I)>14.72.7
Completeness [%]100.0100
Redundancy21.521.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2980.056 M Sodium phosphate monobasic monohydrate 1.344 M Potassium phosphate dibasic

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon