Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6CYD

PDE2 in complex with compound 7

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2014-02-21
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.000
Spacegroup nameP 21 21 21
Unit cell lengths71.940, 91.820, 102.830
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.910 - 1.690
R-factor0.184
Rwork0.182
R-free0.21000
RMSD bond length0.010
RMSD bond angle0.950
Data reduction softwareXDS
Data scaling softwareautoPROC
Phasing softwareREFMAC
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.9101.780
High resolution limit [Å]1.6901.690
Rmerge0.083
Number of reflections77189
<I/σ(I)>13.1
Completeness [%]100.0
Redundancy6.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP29312% PEG8000, 0.1M Hepes pH7.5, 1mM TCEP

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon