6CR1
adalimumab EFab
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 31-ID |
| Synchrotron site | APS |
| Beamline | 31-ID |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2017-02-15 |
| Detector | MAR CCD 165 mm |
| Wavelength(s) | 0.9793 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 125.413, 195.846, 48.779 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 1.540 |
| High resolution limit [Å] | 1.520 | 1.520 |
| Rmerge | 0.115 | |
| Number of reflections | 96198 | |
| <I/σ(I)> | 9.3 | |
| Completeness [%] | 99.6 | |
| Redundancy | 7.4 | |
| CC(1/2) | 0.684 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7.2 | 273 | 15% PEG 3350 and 0.25M potassium nitrate |