6CR1
adalimumab EFab
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 31-ID |
Synchrotron site | APS |
Beamline | 31-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-02-15 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 0.9793 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 125.413, 195.846, 48.779 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 30.000 | 1.540 |
High resolution limit [Å] | 1.520 | 1.520 |
Rmerge | 0.115 | |
Number of reflections | 96198 | |
<I/σ(I)> | 9.3 | |
Completeness [%] | 99.6 | |
Redundancy | 7.4 | |
CC(1/2) | 0.684 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.2 | 273 | 15% PEG 3350 and 0.25M potassium nitrate |