Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

6CNR

aducanumab apo Fab

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2008-10-10
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.987
Spacegroup nameC 1 2 1
Unit cell lengths143.311, 64.126, 67.293
Unit cell angles90.00, 95.85, 90.00
Refinement procedure
Resolution46.500 - 2.090
R-factor0.2122
Rwork0.211
R-free0.23900
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4lf3
RMSD bond length0.002
RMSD bond angle0.605
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwarePHENIX ((1.13_2998: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.160
High resolution limit [Å]2.0902.090
Rmerge0.0570.486
Number of reflections36105
<I/σ(I)>20.3
Completeness [%]99.3
Redundancy3.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29719% PEG 3350 in 100 mM sodium acetate, and 300 mM lithium sulfate

229380

PDB entries from 2024-12-25

PDB statisticsPDBj update infoContact PDBjnumon