6C68
MHC-independent t cell receptor A11
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2011-11-18 |
Detector | MAR CCD 165 mm |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 89.240, 102.555, 118.503 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 34.020 - 2.590 |
R-factor | 0.2046 |
Rwork | 0.202 |
R-free | 0.25810 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3c5z |
RMSD bond length | 0.010 |
RMSD bond angle | 1.290 |
Data reduction software | SCALEIT |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | BUSTER (2.8.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.650 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.095 | 0.487 |
Number of reflections | 32187 | 1262 |
<I/σ(I)> | 23 | |
Completeness [%] | 94.7 | 68.4 |
Redundancy | 9.9 | 4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 20% PEG 4000, 0.1M Tris, pH8.5, 10mM MgCl2 |