6BT5

Human mGlu8 Receptor complexed with L-AP4

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2011-09-10
DetectorRAYONIX MX225HE
Wavelength(s)0.9793
Spacegroup nameI 2 2 2
Unit cell lengths113.650, 166.008, 196.038
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution63.420 - 2.920
R-factor0.2536
Rwork0.253
R-free0.26720
RMSD bond length0.005
RMSD bond angle0.740
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC (5.5.0109)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]67.7603.070
High resolution limit [Å]2.9202.920
Number of reflections38545
<I/σ(I)>16.3
Completeness [%]100.0
Redundancy7.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2953.3 M sodium formate, pH 7.0 and 5 mM L-AP4

219869