Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6BM2

Pol II elongation complex with an abasic lesion at i-1 position

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.1
Synchrotron siteALS
Beamline5.0.1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-12-18
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.0
Spacegroup nameC 1 2 1
Unit cell lengths169.110, 222.270, 193.710
Unit cell angles90.00, 101.28, 90.00
Refinement procedure
Resolution82.922 - 3.403
R-factor0.2203
Rwork0.219
R-free0.24380
RMSD bond length0.002
RMSD bond angle0.522
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]95.9003.580
High resolution limit [Å]3.4003.400
Number of reflections83778
<I/σ(I)>5.2
Completeness [%]99.7
Redundancy3.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP298390mM (NH4)2HPO4/NaH2PO4, pH 6.5, 50mM dioxane, 10mM DTT, 9-12% PEG6000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon