6BBR
Room temperature neutron/X-ray structure of AAC-VIa
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 HF |
Temperature [K] | 298 |
Detector technology | IMAGE PLATE |
Collection date | 2017-08-01 |
Detector | RIGAKU RAXIS IV++ |
Wavelength(s) | 1.5418 |
Spacegroup name | I 1 2 1 |
Unit cell lengths | 51.600, 86.100, 78.800 |
Unit cell angles | 90.00, 94.00, 90.00 |
Refinement procedure
Resolution | 15.000 - 2.300 |
R-factor | 0.222 |
Rwork | 0.221 |
R-free | 0.24580 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6bc6 |
RMSD bond length | 0.010 |
RMSD bond angle | 0.934 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.070 |
High resolution limit [Å] | 2.000 | 4.310 | 2.000 |
Rmerge | 0.059 | 0.042 | 0.489 |
Rmeas | 0.070 | 0.050 | 0.582 |
Rpim | 0.037 | 0.027 | 0.311 |
Number of reflections | 22336 | 2313 | 2171 |
<I/σ(I)> | 19.7 | ||
Completeness [%] | 97.4 | 99.4 | 95.3 |
Redundancy | 3.4 | 3.3 | 3.4 |
CC(1/2) | 0.993 | 0.834 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 285 | 0.1 M Tris, pH 8.5, 0.3 M magnesium chloride, 15-18% PEG8000 |
1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 285 | 0.1 M Tris, pH 8.5, 0.3 M magnesium chloride, 15-18% PEG8000 |