6AJO
Complex form of Uracil DNA glycosylase X and uracil-DNA.
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 7A (6B, 6C1) |
| Synchrotron site | PAL/PLS |
| Beamline | 7A (6B, 6C1) |
| Temperature [K] | 190 |
| Detector technology | CCD |
| Collection date | 2015-04-17 |
| Detector | ADSC QUANTUM 270 |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 36.829, 64.450, 82.900 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 31.976 - 2.269 |
| R-factor | 0.1985 |
| Rwork | 0.192 |
| R-free | 0.25710 |
| Structure solution method | MIR |
| RMSD bond length | 0.021 |
| RMSD bond angle | 2.091 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.320 |
| High resolution limit [Å] | 2.269 | 2.280 |
| Rmerge | 0.098 | 0.938 |
| Number of reflections | 9584 | 415 |
| <I/σ(I)> | 31.2 | |
| Completeness [%] | 99.0 | |
| Redundancy | 11.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 291 | 2.4M sodium malonate pH 7.0, 0.1 M Bis-Tris propane pH 7.0. |