6AEF
PapA2 acyl transferase
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE BM14 |
Synchrotron site | ESRF |
Beamline | BM14 |
Temperature [K] | 298 |
Detector technology | CCD |
Collection date | 2016-02-20 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.97883 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 74.707, 100.668, 128.927 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 39.714 - 2.160 |
R-factor | 0.1998 |
Rwork | 0.198 |
R-free | 0.23150 |
Structure solution method | SAD |
RMSD bond length | 0.005 |
RMSD bond angle | 0.711 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | AutoSol |
Refinement software | PHENIX ((1.11.1_2575)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 39.714 | 2.250 |
High resolution limit [Å] | 2.160 | 2.160 |
Number of reflections | 52880 | |
<I/σ(I)> | 2.24 | |
Completeness [%] | 99.5 | |
Redundancy | 6.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 277.15 | PEG 8000, magnesium chloride, sodium cacodylate |