6A65
Placental protein 13/galectin-13 variant R53HR55N with Tris
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-11-11 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.977 |
Spacegroup name | C 2 2 2 |
Unit cell lengths | 57.316, 91.699, 50.339 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 18.911 - 1.771 |
R-factor | 0.2061 |
Rwork | 0.201 |
R-free | 0.25400 |
Structure solution method | MOLECULAR REPLACEMENT |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 18.911 | 1.810 |
High resolution limit [Å] | 1.770 | 1.770 |
Number of reflections | 13108 | |
<I/σ(I)> | 15.7 | |
Completeness [%] | 98.7 | |
Redundancy | 1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | PEG |