5ZW0
Apo-form PigA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSRRC BEAMLINE BL15A1 |
Synchrotron site | NSRRC |
Beamline | BL15A1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-03-28 |
Detector | RAYONIX MX300HE |
Wavelength(s) | 1.0000 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 79.224, 163.020, 146.140 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.900 - 2.540 |
R-factor | 0.1819 |
Rwork | 0.179 |
R-free | 0.22690 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4l1f |
RMSD bond length | 0.008 |
RMSD bond angle | 0.999 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | CNS |
Refinement software | PHENIX ((1.12_2829: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.640 |
High resolution limit [Å] | 2.540 | 2.540 |
Rmerge | 0.080 | 0.655 |
Number of reflections | 31276 | 3093 |
<I/σ(I)> | 19 | 2.3 |
Completeness [%] | 100.0 | 99.9 |
Redundancy | 6.2 | 6.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291 | 27% polyethylene glycol 600, 0.1M Na-HEPES |