5ZTP
Carbonic anhydrase from Glaciozyma antarctica
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU MICROMAX-007 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-04-26 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 1.54178 |
Spacegroup name | P 31 2 1 |
Unit cell lengths | 82.058, 82.058, 99.280 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 37.950 - 2.960 |
R-factor | 0.181 |
Rwork | 0.179 |
R-free | 0.22640 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3las |
RMSD bond length | 0.012 |
RMSD bond angle | 1.739 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | HKL-3000 |
Refinement software | REFMAC (5.7.0029) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 3.010 |
High resolution limit [Å] | 2.960 | 2.960 |
Number of reflections | 8380 | |
<I/σ(I)> | 10.7 | |
Completeness [%] | 99.7 | |
Redundancy | 6.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 20 mM tris hcl, 50 mM NaCl, 10% glycerol, 0.05 mM Ammonium sulfate |