Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5XSJ

XylFII-LytSN complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL17U1
Synchrotron siteSSRF
BeamlineBL17U1
Temperature [K]100
Detector technologyCCD
Collection date2014-04-27
DetectorRAYONIX MX-225
Wavelength(s)0.9798
Spacegroup nameC 2 2 21
Unit cell lengths105.681, 143.688, 87.133
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.182 - 2.202
R-factor0.1956
Rwork0.194
R-free0.21830
Structure solution methodSAD
RMSD bond length0.008
RMSD bond angle1.058
Phasing softwarePHENIX
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.200
Number of reflections33221
<I/σ(I)>14.61
Completeness [%]97.9
Redundancy6.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.62930.2 M lithium sulfate, 2.0 M ammonium sulfate, 0.1 M MES pH 6.6

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon