Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 4A |
| Synchrotron site | PAL/PLS |
| Beamline | 4A |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2009-04-23 |
| Detector | ADSC QUANTUM 210 |
| Wavelength(s) | 1 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 43.654, 45.214, 70.721 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 27.854 - 1.951 |
| R-factor | 0.1984 |
| Rwork | 0.196 |
| R-free | 0.24140 |
| Structure solution method | SAD |
| RMSD bond length | 0.007 |
| RMSD bond angle | 1.145 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | SOLVE |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 1.950 |
| Number of reflections | 9978 |
| <I/σ(I)> | 19.2 |
| Completeness [%] | 93.2 |
| Redundancy | 4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 4M ammonium acetate, 0.1M sodium acetate |