5X8L
PD-L1 in complex with atezolizumab
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 5C (4A) |
| Synchrotron site | PAL/PLS |
| Beamline | 5C (4A) |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2016-10-23 |
| Detector | ADSC QUANTUM 315r |
| Wavelength(s) | 1.00 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 92.197, 169.793, 206.098 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 29.921 - 3.100 |
| R-factor | 0.2101 |
| Rwork | 0.208 |
| R-free | 0.25580 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.261 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 30.000 |
| High resolution limit [Å] | 3.100 |
| Number of reflections | 57608 |
| <I/σ(I)> | 6.9 |
| Completeness [%] | 97.0 |
| Redundancy | 3.4 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1M Sodium HEPES pH 7.5, 20% w/v PEG8000 |