5WOG
Human Hemoglobin immersed in Liquid Oxygen for 1 minute
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 22-ID |
| Synchrotron site | APS |
| Beamline | 22-ID |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2015-12-14 |
| Detector | MARMOSAIC 300 mm CCD |
| Wavelength(s) | 1.00 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 75.360, 82.890, 83.600 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 41.445 - 1.540 |
| R-factor | 0.1846 |
| Rwork | 0.184 |
| R-free | 0.20650 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2dn1 |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.876 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHENIX |
| Refinement software | PHENIX (1.11.1_2575) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 41.445 | 41.445 | 1.290 |
| High resolution limit [Å] | 1.260 | 5.630 | 1.260 |
| Rmerge | 0.114 | 0.068 | 4.288 |
| Rmeas | 0.118 | 0.071 | 4.465 |
| Number of reflections | 140708 | 1759 | 10365 |
| <I/σ(I)> | 11.61 | 36.86 | 0.63 |
| Completeness [%] | 99.5 | 99.2 | 99.9 |
| Redundancy | 13.699 | 12.823 | 12.78 |
| CC(1/2) | 0.999 | 0.997 | 0.383 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | BATCH MODE | 277.15 | 1 mL of 40 mg/mL hemoglobin + 2.65 M (final concentration) phosphate buffer, topped with 100 uL toluene |