5WO4
JAK1 complexed with compound 28
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-09-30 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 1.00 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 42.570, 173.360, 44.650 |
Unit cell angles | 90.00, 93.94, 90.00 |
Refinement procedure
Resolution | 26.940 - 1.840 |
R-factor | 0.1876 |
Rwork | 0.186 |
R-free | 0.21080 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.010 |
RMSD bond angle | 1.010 |
Data reduction software | XDS |
Data scaling software | autoPROC |
Phasing software | autoBUSTER |
Refinement software | BUSTER (2.11.4) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 173.000 | 1.846 |
High resolution limit [Å] | 1.840 | 1.840 |
Rmerge | 0.071 | 0.545 |
Number of reflections | 55407 | 548 |
<I/σ(I)> | 11.3 | |
Completeness [%] | 99.5 | 99.8 |
Redundancy | 3.7 | 3.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6 | 277 | 100 mM MES pH 6.0, 30% (w/v) PEG 6000 |