Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5W4F

Importin binding to pol Mu NLS peptide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2013-07-26
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.0
Spacegroup nameP 21 21 21
Unit cell lengths79.005, 89.819, 99.541
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.936 - 1.984
R-factor0.1709
Rwork0.170
R-free0.19880
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5e6q
RMSD bond length0.008
RMSD bond angle1.081
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX ((1.10.1_2155: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.010
High resolution limit [Å]1.9801.980
Rmerge0.0690.380
Number of reflections48426
<I/σ(I)>11.9
Completeness [%]97.4
Redundancy6.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP72930.1 M HEPES 0.8 M Sodium Citrate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon